EZLabpure™ Peroxide cured silicone transparent tube 9.5mm (3/8") ID X 19.05mm (3/4") OD
SKU:
Description
Features
Applications
Sterilization Method
Compatible Container
SKU Nomenclature
Safety Usage Guidelines
Safety Usage Guidelines
Specification
Documentation
Videos
EZLabpure™ Peroxide Grade Silicone Tubing is designed for non-critical fluid transfer, peristaltic pump use, and general engineering applications. EZLabpure™ is transparent and is made of high-quality peroxide silicone rubber tubing with excellent physical properties including tensile strength, flexibility, and resiliency. • Meets FDA 21 CFR 177.2600 • Manufactured and Packaged in Dust Free environment • Odorless and Tasteless • Excellent flex fatigue resistance to enhance peristaltic pump life • Temperature resistance -80°C to + 230°C • BPA and Phthalate Free • TSE/BSE Free / ROHS compliant
All standard dimensions are in mm and Inch dimensions are for reference only.
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enable...
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enable...
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enable...
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enable...
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enable...
Availability
In Stock
In Stock
In Stock
In Stock
In Stock
Collection
All
All
All
All
All
Shipping Weight
2.0 lb
2.0 lb
2.0 lb
2.0 lb
2.0 lb
Sold By
CPC
CPC
CPC
CPC
CPC
Specification
×
Description
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enables users to transfer media easily with less risk of operator error. The connectors’ robust design provides reliable performance without the need for clamps, fixtures or tube welders. Biopharmaceutical manufacturers can make sterile connections with the quality and market availability they expect from the leader in single-use connection.
CLICK-PULL-TWIST Design – Intuitive three-step connection process that reduces the risk of operator error.
Membrane Pull Tabs – Enable simultaneous and secure removal of both membranes for a reliable sterile connection.
Robust Construction – Delivers repeatable, dependable performance without the need for additional hardware.
Integrated Lock Ring – Secures the final connection and prevents accidental disassembly.
CPC Click Confirmation – Provides an audible “click” to confirm proper and complete assembly.
Sterile media and buffer transfer in biopharmaceutical manufacturing
Upstream bioprocess connections for bioreactors and seed trains
Downstream processing integration for filtration and chromatography systems
Cell and gene therapy fluid handling in closed systems
Single-use sterile assemblies for secure aseptic connections
Operating Conditions (Fluid Transfer)
Pressure
60 psi (4.1 bar)
Temperature
39°F to 104°F (4°C to 40°C)
Typical Flow Rate
Cv ~14.4 max
Materials
Connector
Polycarbonate (white), USP Class VI, ADCF
Lock Ring
Polycarbonate (blue), USP Class VI, ADCF
Pull Tabs
Polycarbonate (blue, standard version), USP Class VI, ADCF
Pull Tabs
Polycarbonate (white, HT version), USP Class VI, ADCF
Caps
Polypropylene (clear), USP Class VI, ADCF
Seals
Silicone (clear), platinum-cured, USP Class VI, ADCF
Membrane
Polyethylene (standard version), USP Class VI, ADCF
Membrane
Hydrophobic polyethersulfone (HT version), USP Class VI
Sterilization
Gamma
Up to 50 kGy irradiation
Autoclave
High Temp (HT) Version: Up to 266°F (130°C) for 30 minutes
Other
Termination Size
1/2" ID hose barb (12.7 mm), 3/8" hose barb (9.5 mm) and 3/4" sanitary
Cv Value
Cv ~14.4 max
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).
WARNING:Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customer’s responsibility to test the suitability of Colder products in their own application conditions
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enables users to transfer media easily with less risk of operator error. The connectors’ robust design provides reliable performance without the need for clamps, fixtures or tube welders. Biopharmaceutical manufacturers can make sterile connections with the quality and market availability they expect from the leader in single-use connection.
CLICK-PULL-TWIST Design – Intuitive three-step connection process that reduces the risk of operator error.
Membrane Pull Tabs – Enable simultaneous and secure removal of both membranes for a reliable sterile connection.
Robust Construction – Delivers repeatable, dependable performance without the need for additional hardware.
Integrated Lock Ring – Secures the final connection and prevents accidental disassembly.
CPC Click Confirmation – Provides an audible “click” to confirm proper and complete assembly.
Sterile media and buffer transfer in biopharmaceutical manufacturing
Upstream bioprocess connections for bioreactors and seed trains
Downstream processing integration for filtration and chromatography systems
Cell and gene therapy fluid handling in closed systems
Single-use sterile assemblies for secure aseptic connections
Operating Conditions (Fluid Transfer)
Pressure
60 psi (4.1 bar)
Temperature
39°F to 104°F (4°C to 40°C)
Typical Flow Rate
Cv ~14.4 max
Materials
Connector
Polycarbonate (white), USP Class VI, ADCF
Lock Ring
Polycarbonate (blue), USP Class VI, ADCF
Pull Tabs
Polycarbonate (blue, standard version), USP Class VI, ADCF
Pull Tabs
Polycarbonate (white, HT version), USP Class VI, ADCF
Caps
Polypropylene (clear), USP Class VI, ADCF
Seals
Silicone (clear), platinum-cured, USP Class VI, ADCF
Membrane
Polyethylene (standard version), USP Class VI, ADCF
Membrane
Hydrophobic polyethersulfone (HT version), USP Class VI
Sterilization
Gamma
Up to 50 kGy irradiation
Autoclave
High Temp (HT) Version: Up to 266°F (130°C) for 30 minutes
Other
Termination Size
1/2" ID hose barb (12.7 mm), 3/8" hose barb (9.5 mm) and 3/4" sanitary
Cv Value
Cv ~14.4 max
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).
WARNING:Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customer’s responsibility to test the suitability of Colder products in their own application conditions
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enables users to transfer media easily with less risk of operator error. The connectors’ robust design provides reliable performance without the need for clamps, fixtures or tube welders. Biopharmaceutical manufacturers can make sterile connections with the quality and market availability they expect from the leader in single-use connection.
CLICK-PULL-TWIST Design – Intuitive three-step connection process that reduces the risk of operator error.
Membrane Pull Tabs – Enable simultaneous and secure removal of both membranes for a reliable sterile connection.
Robust Construction – Delivers repeatable, dependable performance without the need for additional hardware.
Integrated Lock Ring – Secures the final connection and prevents accidental disassembly.
CPC Click Confirmation – Provides an audible “click” to confirm proper and complete assembly.
Sterile media and buffer transfer in biopharmaceutical manufacturing
Upstream bioprocess connections for bioreactors and seed trains
Downstream processing integration for filtration and chromatography systems
Cell and gene therapy fluid handling in closed systems
Single-use sterile assemblies for secure aseptic connections
Operating Conditions (Fluid Transfer)
Pressure
60 psi (4.1 bar)
Temperature
39°F to 104°F (4°C to 40°C)
Typical Flow Rate
Cv ~14.4 max
Materials
Connector
Polycarbonate (white), USP Class VI, ADCF
Lock Ring
Polycarbonate (blue), USP Class VI, ADCF
Pull Tabs
Polycarbonate (blue, standard version), USP Class VI, ADCF
Pull Tabs
Polycarbonate (white, HT version), USP Class VI, ADCF
Caps
Polypropylene (clear), USP Class VI, ADCF
Seals
Silicone (clear), platinum-cured, USP Class VI, ADCF
Membrane
Polyethylene (standard version), USP Class VI, ADCF
Membrane
Hydrophobic polyethersulfone (HT version), USP Class VI
Sterilization
Gamma
Up to 50 kGy irradiation
Autoclave
High Temp (HT) Version: Up to 266°F (130°C) for 30 minutes
Other
Termination Size
1/2" ID hose barb (12.7 mm), 3/8" hose barb (9.5 mm) and 3/4" sanitary
Cv Value
Cv ~14.4 max
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).
WARNING:Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customer’s responsibility to test the suitability of Colder products in their own application conditions
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enables users to transfer media easily with less risk of operator error. The connectors’ robust design provides reliable performance without the need for clamps, fixtures or tube welders. Biopharmaceutical manufacturers can make sterile connections with the quality and market availability they expect from the leader in single-use connection.
CLICK-PULL-TWIST Design – Intuitive three-step connection process that reduces the risk of operator error.
Membrane Pull Tabs – Enable simultaneous and secure removal of both membranes for a reliable sterile connection.
Robust Construction – Delivers repeatable, dependable performance without the need for additional hardware.
Integrated Lock Ring – Secures the final connection and prevents accidental disassembly.
CPC Click Confirmation – Provides an audible “click” to confirm proper and complete assembly.
Sterile media and buffer transfer in biopharmaceutical manufacturing
Upstream bioprocess connections for bioreactors and seed trains
Downstream processing integration for filtration and chromatography systems
Cell and gene therapy fluid handling in closed systems
Single-use sterile assemblies for secure aseptic connections
Operating Conditions (Fluid Transfer)
Pressure
60 psi (4.1 bar)
Temperature
39°F to 104°F (4°C to 40°C)
Typical Flow Rate
Cv ~14.4 max
Materials
Connector
Polycarbonate (white), USP Class VI, ADCF
Lock Ring
Polycarbonate (blue), USP Class VI, ADCF
Pull Tabs
Polycarbonate (blue, standard version), USP Class VI, ADCF
Pull Tabs
Polycarbonate (white, HT version), USP Class VI, ADCF
Caps
Polypropylene (clear), USP Class VI, ADCF
Seals
Silicone (clear), platinum-cured, USP Class VI, ADCF
Membrane
Polyethylene (standard version), USP Class VI, ADCF
Membrane
Hydrophobic polyethersulfone (HT version), USP Class VI
Sterilization
Gamma
Up to 50 kGy irradiation
Autoclave
High Temp (HT) Version: Up to 266°F (130°C) for 30 minutes
Other
Termination Size
1/2" ID hose barb (12.7 mm), 3/8" hose barb (9.5 mm) and 3/4" sanitary
Cv Value
Cv ~14.4 max
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).
WARNING:Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customer’s responsibility to test the suitability of Colder products in their own application conditions
Manufactured by CPC®, AseptiQuik® C Connectors provide quick and easy sterile connections, even in non-sterile environments. AseptiQuik® C connectors’ “CLICK-PULL-TWIST” design enables users to transfer media easily with less risk of operator error. The connectors’ robust design provides reliable performance without the need for clamps, fixtures or tube welders. Biopharmaceutical manufacturers can make sterile connections with the quality and market availability they expect from the leader in single-use connection.
CLICK-PULL-TWIST Design – Intuitive three-step connection process that reduces the risk of operator error.
Membrane Pull Tabs – Enable simultaneous and secure removal of both membranes for a reliable sterile connection.
Robust Construction – Delivers repeatable, dependable performance without the need for additional hardware.
Integrated Lock Ring – Secures the final connection and prevents accidental disassembly.
CPC Click Confirmation – Provides an audible “click” to confirm proper and complete assembly.
Sterile media and buffer transfer in biopharmaceutical manufacturing
Upstream bioprocess connections for bioreactors and seed trains
Downstream processing integration for filtration and chromatography systems
Cell and gene therapy fluid handling in closed systems
Single-use sterile assemblies for secure aseptic connections
Operating Conditions (Fluid Transfer)
Pressure
60 psi (4.1 bar)
Temperature
39°F to 104°F (4°C to 40°C)
Typical Flow Rate
Cv ~14.4 max
Materials
Connector
Polycarbonate (white), USP Class VI, ADCF
Lock Ring
Polycarbonate (blue), USP Class VI, ADCF
Pull Tabs
Polycarbonate (blue, standard version), USP Class VI, ADCF
Pull Tabs
Polycarbonate (white, HT version), USP Class VI, ADCF
Caps
Polypropylene (clear), USP Class VI, ADCF
Seals
Silicone (clear), platinum-cured, USP Class VI, ADCF
Membrane
Polyethylene (standard version), USP Class VI, ADCF
Membrane
Hydrophobic polyethersulfone (HT version), USP Class VI
Sterilization
Gamma
Up to 50 kGy irradiation
Autoclave
High Temp (HT) Version: Up to 266°F (130°C) for 30 minutes
Other
Termination Size
1/2" ID hose barb (12.7 mm), 3/8" hose barb (9.5 mm) and 3/4" sanitary
Cv Value
Cv ~14.4 max
Cv values are based on gpm and psi, and Ipm and bar (shown in parentheses).
WARNING:Pressure, temperature, chemicals and operating environment can affect the performance of couplings. It is the customer’s responsibility to test the suitability of Colder products in their own application conditions
Assess your fluid handling volumes, sterility requirements, compatibility with solvents or reagents, and workflow endpoints. Foxx’s technical support team can assist in selecting assemblies and filtration components suited to your process.
Biotech, pharmaceutical manufacturing, vaccine production, research laboratories, clinical development, and diagnostic centres widely use Foxx single-use systems and consumables.
Yes. With global manufacturing facilities and strict quality control, Foxx products meet regulatory requirements in major markets including the US, EU, and Asia for scientific, clinical, and manufacturing applications.
Labs should follow regulatory guidelines for sterility assurance levels, validate fluid handling pathways, perform risk assessments per relevant standards (e.g., FDA, USP), and maintain traceability documentation for audit readiness. (Industry practice)
Yes. The company’s cleanroom manufacturing and quality certifications make its products suitable for Good Manufacturing Practice (GMP) environments where sterility and documentation standards are required.
Foxx Life Sciences offers Autofil® 2, EZlabpure™ and APEX™ bottle top filters, EZlabpure™ and EZFlow syringe filters, membrane disc filters, vent filters, and cell strainers engineered for high-purity filtration in analytical labs, bioprocessing, and cell culture workflows.
Foxx stands out for its ISO-certified quality, USP Class VI materials, extensive SKU portfolio with patented designs, rapid shipment, and global manufacturing footprint, providing superior compliance, performance, and cost value.
Foxx offers custom single-use solutions and assemblies designed to meet unique workflow requirements, enabling bespoke fluid paths, connectors, and tailored assemblies to optimize specific lab processes.
Standard Foxx products typically ship within 24–48 hours, while Made-to-Order (MTO) or custom SUT assemblies generally ship in 4–6 weeks, balancing speed with tailored specifications.
Single-use systems reduce contamination risk, eliminate cleaning and sterilization validation needs, cut turnaround times, lower labour and water use, and improve overall operational efficiency.
Foxx products are manufactured under ISO 13485 quality management systems in ISO Class 7 certified cleanrooms, use USP Class VI materials, and many are FDA registered. This ensures reliability, compliance, and suitability for regulated environments.
Single-Use Technology refers to disposable fluid handling and storage assemblies used in biopharmaceutical manufacturing and labs that eliminate traditional cleaning and sterilization processes, reducing contamination risk and operational complexity.
Foxx Life Sciences provides a broad range of life science and bioprocess consumables, including single-use systems (SUS), custom tubing & bottle assemblies, filtration products, lab safety equipment, glassware, plasticware, caps & gaskets, connectors, vent filters, and stainless-steel components for research, biotech, and pharmaceutical applications.